1
A Truck Operated Cell Switch (TOC) provides which of the following?
A remote means of tripping the breaker
A remote means of closing the breaker
Prevents unauthorized circuit breaker operation
Indicates the movement of the breaker into and out of the "Connected" position
2
An operations counter counts the open and close operations of a low voltage power circuit breaker.
True
False
3
Current transformers used in low voltage power circuit breakers, to monitor and reduce the current to useful levels, are also known as _______________.
Trip unit
Arc extinguisher
Primary contacts
Current sensors
4
A component of the Arc Extinguisher in a low voltage power circuit breaker, which elongates and cools the arc, is called an arc chute.
True
False
5
All low voltage power breakers that meet applicable ANSI standards are capable of continuous operation at 100% of their current rating.
True
False
6
The frame rating or frame size of a low voltage power circuit breaker refers to the _________________ rating of the breaker.
Continuous current
Short time
Interrupting
None of the above
7
The position in which the low voltage power circuit breaker is fully connected and functional is the __________________.
Connected position
Test position
Disconnected position
Withdrawn position
8
A low voltage power circuit breaker's source of intelligence is its _______________.
Trip unit
Arc extinguisher
Primary contacts
Operating mechanism
None of the above
9
The nominal voltage range for low voltage power circuit breakers in the domestic market governed by ANSI standards is ______ to 600 Volts AC.
120
208
240
480
1000
10
The operating mechanism springs of both manually operated and electrically operated low voltage power circuit breakers can be charged manually.
True
False
11
ANSI standards require low voltage power circuit breakers to have integrally mounted trip units.
True
False
12
A ______ ______ is an electromechanical device used to provide for remote controlled tripping of a manually operated low voltage power circuit breaker.
Spring Release
Undervoltage Release
Bell Alarm
Shunt Trip
13
When a low voltage power circuit breaker opens, its arcing contacts part before the main contacts part in order to draw any arcs formed away from the main contacts.
True
False
14
In the __________________, the low voltage power circuit breaker has no electrical connections, and is far enough out of its enclosure to permit inspection and maintenance.
Connected position
Test position
Disconnected position
Withdrawn position
15
Which testing standard most influences the design and testing of low voltage power circuit breakers used in the United States?
NEMA 80 - A02
UL 1866
IEC 947-2
ANSI C37.50
16
Of the two most common low voltage power circuit breaker mounting methods, the fixed configuration is most commonly used because it is less expensive.
True
False
17
The ____________ rating of a power breaker is one of the main features that differentiates it from other types of circuit breakers.
Continuous current
Short time
Interrupting
Withstand
None of the above
18
Primary connectors between a low voltage power circuit breaker and a bus are called ______________.
Bus plugs
Finger clusters
Contact switches
Bus adapters
None of the above
19
A three-phase low voltage power circuit breaker would have two sets of primary contacts.
True
False
20
A typical microprocessor-based trip unit used with a low voltage power circuit breaker can offer the following capabilities, except:
Programming
Monitoring
Diagnostics
Communication
All are offered