101 Basic Series - Module 28 - CEU Education
Your final score on this exam will be emailed to you for your records.
First name:
Last name:
Company name:
E-Mail Address
City
State
NO STATE
AL
AK
AS
AZ
AR
CA
CO
CT
DE
DC
FM
FL
GA
GU
HI
ID
IL
IN
IA
KS
KY
LA
ME
MH
MD
MA
MI
MN
MS
MO
MT
NE
NV
NH
NJ
NM
NY
NC
ND
MP
OH
OK
OR
PA
PR
PW
RI
SC
SD
TN
TX
UT
VT
VI
VA
WA
WV
WI
WY
Province (Optional)
Country (Optional)
1
Lower let-through voltage offers lesser surge protection for downstream loads.
True
False
2
The ANSI 62.41 standard classifies outside and service entrance circuits as:
Category A
Category B
Category C
3
________ is usually accomplished by attaching a conductor to a metal electrode (rod), which is then buried in the ground.
Grounding
Neutralizing
Energizing
Noise Suppression
4
Lower impedance translates directly into higher let-through voltage.
True
False
5
The design goal of a surge protection device is to divert as much of a transient power disturbance away from the load as possible.
True
False
6
When selenium cells are used in parallel with MOVs, there is a large advantage gained in performance, cost or application flexibility.
True
False
7
Noise can be brought about by the differences in ground potentials throughout an electrical system.
True
False
8
In AC power applications, over 99% of SPDs incorporate SAD technology because of the high-energy capability and reliable performance as a clamping device.
True
False
9
In an industrial application, the first stage of protection is provided at the service entrance, with an SPD integrated into the switchboard or main panelboard.
True
False
10
With proper implementation of surge protection devices and shielding equipment, the vast majority of lightning losses are preventable.
True
False
11
Swells are often caused when there is a sudden load decrease.
True
False
12
Let-through voltage is the amount of voltage that is not suppressed by the SPD and passes through to the load.
True
False
13
Sags can affect operating coils of motor starters, which are designed to drop off-line at less than ________ voltage.
100%
90%
85%
75%
14
The integrated design of SPDs has solved many problems associated with the standalone approach providing improved suppression performance.
True
False
15
The ANSI 62.41 standard classifies feeders and short branch circuits as:
Category A
Category B
Category C
16
A surge is a single, non-repeating voltage distortion of less than 0.5 cycles in duration.
True
False
17
When exposed to IEEE-defined test waveforms and UL 1449 2nd edition test results, the SAD and MOV devices have the same Suppression Voltage ratings.
True
False
18
If the maximum surge is 10 kA, why do many suppliers suggest installing a device that can handle up to 250 kA per phase?
Minimum protection
Maximum protection
Life protection
Life expectancy
19
Selenium cells are metallic rectifiers (diodes) with a maximum reverse voltage of only 25 VDC; so that many cells are required for higher voltages.
True
False
20
Transients and surges are different kinds of disturbances.
True
False
Created and managed with SmartLite WebQuiz XP