101 Basic Series - Module 04 - Post Assessment
Your final score on this exam will be emailed to you for your records.
First name:   Last name:  
Company name:   E-Mail Address  
City   State  
Province (Optional)   Country (Optional)  
1
The amount of coupling that takes place between the two windings in a transformer is the ________.
2
The lower the heat loss in a transformer, the lower the efficiency.
3
Fine tuning the input voltage to get the desired output is called ________, which allows for consistency in output voltage.
4
If each secondary of a single phase transformer is rated 120V and 100A, when connected in series, they would equal 240V, 100A or 24KVA.
5
The transformer ________ is used to provide a controlled path for the magnetic flux generated in the transformer by current flowing through the windings.
6
When a transformer transfers electrical energy from one circuit to another, it changes the frequency.
7
The most common rating for transformers is in ________.
8
If the turns ratio of a transformer is 5:1, and the primary has 100 turns, then there must be________ turns on the secondary.
9
The transformer core is used to provide a controlled path for the magnetic flux generated in the transformer by current flowing through the ________.
10
A transformer sealed in an enclosure capable of moving excessive heat away from the core and coils without ventilation openings or other heat dissipation means is called a ________.
11
Voltages induced in the core are called Eddy Currents, and are helpful.
12
If the secondary winding has fewer turns than the primary winding, the transformer is called a step-up transformer.
13
The input side of a transformer is called the primary or primary side because this is where the main electrical connection to the utility or power source occurs.
14
Current and Potential are two types of ________ transformers.
15
Given that Power is always equal on both sides of the transformer, when voltage increases, amperage ________.
16
When two secondary windings of a single phase transformer are connected in series, their voltage is added. When two secondary windings are connected in parallel, their currents are ________.
17
A transformer used primarily to couple electrical energy from a power supply line to a circuit system is called a ________ transformer.
18
The ratio between the number of actual turns of wire in each coil is the key to determining what the output voltage will be.
19
A transformer designed to operate in air without requiring the assistance of a liquid to dissipate excess heat is called a ________.
20
In a step-up transformer, the secondary voltage is ________.