1
The amount of coupling that takes place between the two windings in a transformer is the ________.
Coefficient of coupling
Coefficient of coupling
Eddy Current
Copper loss
Basic impulse level
Expansion/contraction of the laminations
2
The lower the heat loss in a transformer, the lower the efficiency.
True
False
3
Fine tuning the input voltage to get the desired output is called ________, which allows for consistency in output voltage.
Normal taps
Power taps
Voltage taps
Current taps
4
If each secondary of a single phase transformer is rated 120V and 100A, when connected in series, they would equal 240V, 100A or 24KVA.
True
False
5
The transformer ________ is used to provide a controlled path for the magnetic flux generated in the transformer by current flowing through the windings.
Input connections
Output connections
Windings (or coils)
Core
6
Given that Power is always equal on both sides of the transformer, when voltage increases, amperage ________.
Increases
Decreases
Stays the same
7
Current and Potential are two types of ________ transformers.
Distribution
Power
Isolation
Rectifier
Instrument
8
The input side of a transformer is called the primary or primary side because this is where the main electrical connection to the utility or power source occurs.
True
False
9
If the secondary winding has fewer turns than the primary winding, the transformer is called a step-up transformer.
True
False
10
Voltages induced in the core are called Eddy Currents, and are helpful.
True
False
11
A transformer sealed in an enclosure capable of moving excessive heat away from the core and coils without ventilation openings or other heat dissipation means is called a ________.
Dry type transformer
Liquid-filled transformer
Encapsulated transformer
Isolation transformer
None of the above
12
The transformer core is used to provide a controlled path for the magnetic flux generated in the transformer by current flowing through the ________.
Input connections
Output connections
Windings (or coils)
Core
13
If the turns ratio of a transformer is 5:1, and the primary has 100 turns, then there must be________ turns on the secondary.
5
100
150
20
14
The most common rating for transformers is in ________.
Gigavoltamperes
Megavoltamperes
Kilovoltamperes
Millivoltamperes
15
When a transformer transfers electrical energy from one circuit to another, it changes the frequency.
True
False
16
When two secondary windings of a single phase transformer are connected in series, their voltage is added. When two secondary windings are connected in parallel, their currents are ________.
Added
Subtracted
Multiplied
Divided
17
A transformer used primarily to couple electrical energy from a power supply line to a circuit system is called a ________ transformer.
Distribution
Power
Isolation
Rectifier
Instrument
18
The ratio between the number of actual turns of wire in each coil is the key to determining what the output voltage will be.
True
False
19
A transformer designed to operate in air without requiring the assistance of a liquid to dissipate excess heat is called a ________.
Dry type transformer
Liquid-filled transformer
Encapsulated transformer
Isolation transformer
None of the above
20
In a step-up transformer, the secondary voltage is ________.
Lower
Higher
The same
Created and managed with SmartLite WebQuiz XP