101 Basic Series - Module 06 - Post Assessment
Your final score on this exam will be emailed to you for your records.
First name:   Last name:  
Company name:   E-Mail Address  
City   State  
Province (Optional)   Country (Optional)  
1
The rotary arc technology is not effective over as wide a range of short circuit currents and voltages as the puffer technology.
2
IEC stands for: __________ .
3
One drawback of the medium voltage power circuit breaker is that the closing strings cannot be charged manually.
4
A medium voltage power circuit breaker uses a stored-energy operating mechanism, which uses motor driven hydraulics, to open the circuit breaker.
5
Short Circuit Current in the ANSI ratings chart is equivalent to the __________  in the IEC ratings chart.
6
Which enclosure assembly method separates compartments within the switchgear by metal barriers?
7
Which enclosure assembly method does not necessarily separate compartments within the switchgear by metal barriers, and is common among low voltage equipment?
8
Which is not a position of a drawout mounted medium voltage power circuit breaker?
9
If the dielectric in a vacuum interrupter does not reach sufficient strength fast enough, the arc will re-ignite.
10
Microprocessor-based trip intelligence is superior to electromagnetic-based trip intelligence because it provides all the features of several electromagnetic relays in one box.
11
The puffer extinguishing method is far less complicated than the rotary arc method.
12
A medium voltage power circuit breaker must meet the requirements of __________ , __________ ,__________ , __________ , and __________  to be considered "world-class".
13
The highest voltage at which the breaker can operate, according to IEC charts, is the __________.
14
The spiral-shaped, copper-chrome contacts that provide a self-induced magnetic effect is a very inefficient arc control method.
15
The amount of current the breaker can carry continuously at 60 cycles without exceeding the temperature rise limit, according to ANSI charts, is called ___________.
16
Vacuum interrupters for circuit breaker duty must be capable of interrupting currents of 16 to 75 kA at voltages up to 38 kV.
17
A type of medium voltage power circuit breaker no longer in common use in switchgear is the Magnetic Air Type circuit breaker.
18
The insulating medium between two contacts, (such as air, gas, or ceramic) is called ____________.
19
The most common type of microprocessor-based trip intelligence used with a medium voltage power circuit breaker, which functions to detect a defective line or apparatus and dangerous or undesirable system conditions is called a ___________.
20
Continuous Current in the ANSI ratings chart is equivalent to the __________ in the IEC ratings chart.